Flat 10A to 16A power relay
Features
1. Only 11mm in
height
2. High switching capacity up to 16A
3. Plastic sealed type standard |
|
Approx. the actual size |
Applications
1. Home appliance, Industrial control
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact
data
|
Arrangement
|
1 Form A (SPST)
|
1 Form C (SPDT)
|
Contact material
|
Ag Alloy
|
Initial contact
resistance
|
100m§Ù max.
|
Rated load, resistive
|
16A 30VDC
16A 250VAC
|
10A 30VDC
10A 250VAC
|
Maximum switching
current
|
16A
|
10A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
300W
2,500VA
|
Maximum switching
voltage
|
110VDC
380VAC
|
Coil data
Coil
data
|
Nominal voltage
|
5VDC to 48VDC
|
Nominal power consumption1)
|
200mW, 450mW
|
Operate voltage2)
|
80% of nominal voltage
|
Release voltage3)
|
5% of nominal voltage
|
1), 2), 3) The
values depend on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
10ms max. at nominal
voltage
|
Release time
|
5ms max. at nominal voltage
|
Initial insulation
resistance
|
100 M§Ù min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
750VACrms for 1 minute
1,500VACrms for 1 minute
|
Expected life
|
Mechanical:
Electrical:
|
More than 5,000,000 operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10¡55Hz dual amplitude:
1.5mm
10¡55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Ambient temperature
|
£40¡É to £«85¡É (with no
icing)
|
Humidity
|
35% to 85% RH
|
Weight
|
10g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for
reference, part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(§Ù¡¾10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(mW)
|
Standard coil, 1 Form
A
|
HR80A DC05
|
5
|
55.5
|
90
|
4.0
|
0.25
|
6.5
|
450
|
HR80A DC06
|
6
|
80
|
75
|
4.8
|
0.30
|
7.8
|
HR80A DC09
|
9
|
180
|
50
|
7.2
|
0.45
|
11.7
|
HR80A DC12
|
12
|
320
|
37.5
|
9.6
|
0.60
|
15.6
|
HR80A DC18
|
18
|
720
|
25
|
14.4
|
0.90
|
23.4
|
HR80A DC24
|
24
|
1,280
|
18.75
|
19.2
|
1.20
|
31.2
|
HR80A DC48
|
48
|
3,840
|
12.5
|
38.4
|
2.40
|
62.4
|
600
|
Sensitive
coil, 1 Form A
|
HR80A DC05H
|
5
|
125
|
40
|
4.0
|
0.25
|
6.5
|
200
|
HR80A DC06H
|
6
|
180
|
33.3
|
4.8
|
0.30
|
7.8
|
HR80A DC09H
|
9
|
405
|
22.2
|
7.2
|
0.45
|
11.7
|
HR80A DC12H
|
12
|
720
|
16.7
|
9.6
|
0.60
|
15.6
|
HR80A DC18H
|
18
|
1,620
|
11.1
|
14.4
|
0.90
|
23.4
|
HR80A DC24H
|
24
|
2,880
|
8.33
|
19.2
|
1.20
|
31.2
|
Standard
coil, 1 Form C
|
HR80C DC05
|
5
|
55.5
|
90
|
4.0
|
0.25
|
6.5
|
450
|
HR80C DC06
|
6
|
80
|
75
|
4.8
|
0.30
|
7.8
|
HR80C DC09
|
9
|
180
|
50
|
7.2
|
0.45
|
11.7
|
HR80C DC12
|
12
|
320
|
37.5
|
9.6
|
0.60
|
15.6
|
HR80C DC18
|
18
|
720
|
25
|
14.4
|
0.90
|
23.4
|
HR80C DC24
|
24
|
1,280
|
18.75
|
19.2
|
1.20
|
31.2
|
HR80C DC48
|
48
|
3,840
|
12.5
|
38.4
|
2.40
|
62.4
|
600
|
Sensitive coil,
1 Form C
|
HR80C DC05H
|
5
|
125
|
40
|
4.0
|
0.25
|
6.5
|
200
|
HR80C DC06H
|
6
|
180
|
33.3
|
4.8
|
0.30
|
7.8
|
HR80C DC09H
|
9
|
405
|
22.2
|
7.2
|
0.45
|
11.7
|
HR80C DC12H
|
12
|
720
|
16.7
|
9.6
|
0.60
|
15.6
|
HR80C DC18H
|
18
|
1,620
|
11.1
|
14.4
|
0.90
|
23.4
|
HR80C DC24H
|
24
|
2,880
|
8.33
|
19.2
|
1.20
|
31.2
|
Note: All values in the chart are measured at
23¡É
|