1 Pole 10A medium load control relay

Features

1. High sensitive 360mW type available
2. High surge strength 5,000V
3. DIL pitch terminal
4. Sealed construction standard

Approx. the actual size
Applications

1. Industrial control, Home appliance

Dimensions (mm)

To convert into inches, multiply by 0.03937

PC Board Layout

Copper-side view


Schematic

Copper-side view

Contact data

Contact data

Arrangement

1 Form A (SPST), 1 Form C (SPDT)

Contact material

Ag Alloy

Initial contact resistance

100m§Ù max.

Rated load, resistive

10A 28VDC
10A 120VAC
Maximum switching current
10A

Maximum switching
capacity

with DC voltage:
with AC voltage:

300W
1,200VA

Maximum switching voltage

110VDC
380VAC

Coil data

Coil data
Nominal voltage
3VDC to 48VDC
Nominal power consumption1)
360mW, 450mW
Operate voltage2)
75% of nominal voltage
Release voltage3)
10% of nominal voltage

1), 2), 3) The values depend on coil voltage, see Part selection chart

General data

General data
Operate time
7ms max. at nominal voltage
Release time
4ms max. at nominal voltage
Initial insulation resistance
500 M§Ù min. (500VDC)
Dielectric strength
Between open contacts:
Between contacts & coil:
750VACrms for 1 minute
2,000VACrms for 1 minute
Surge strength
Between contacts & coil:
5,000V
Expected life
Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated load
Vibration resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance
Functional:
Destructive:
10G min.
100G min.
Ambient temperature
£­25¡É to £«70¡É (with no icing)
Humidity
35% to 85% RH
Weight
11g approx.

Note: The above figures are initial values

Part number description


Part number description is provided for reference, part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer specifications
are possible; please contact HR.

Part selection

¡à Fill in the contact code to the part number by selecting it from the contact rating in part
number description

Part number
Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
Max
voltage
(VDC)
Nominal
power
(mW)
Standard coil
HR95¡àDC03
3
20
150
2.25
0.3
3.9
450
HR95¡àDC05
5
56
90
3.75
0.5
6.5
HR95¡àDC06
6
80
75
4.50
0.6
7.8
HR95¡àDC09
9
180
50
6.75
0.9
11.7
HR95¡àDC12
12
320
37.5
9.00
1.2
15.6
HR95¡àDC18
18
720
25
13.5
1.8
23.4
HR95¡àDC24
24
1,280
18.75
18.0
2.4
31.2
HR95¡àDC48
48
3,780
12.7
36.0
4.8
62.4
610
Sensitive coil
HR95¡àDC03H
3
25
120
2.25
0.3
3.9
360
HR95¡àDC05H
5
69
72
3.75
0.5
6.5
HR95¡àDC06H
6
100
60
4.50
0.6
7.8
HR95¡àDC09H
9
225
40
6.75
0.9
11.7
HR95¡àDC12H
12
400
30
9.00
1.2
15.6
HR95¡àDC18H
18
900
20
13.5
1.8
23.4
HR95¡àDC24H
24
1,600
15
18.0
2.4
31.2

Note: All values in the chart are measured at 23¡É