12A, 1-Pole cubic relay
Features
1. Universal size and foot
print
2. Highest carry current capability of its kind, 15A
3. Design conforms to various safety standard
4. Sealed construction standard |
|
Applications
1.Home appliance, Office equipment, Vending
machine, Industrial control
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact
data
|
Arrangement
|
1 Form A (SPST) to 1 Form
C (SPDT)
|
Contact material
|
AgCdO
|
Initial contact
resistance
|
100m§Ù max.
|
Rated load, resistive
|
12A 24VDC
12A 120VAC
10A 250VAC
|
Maximum switching
current
|
15A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
240W
2,500VA
|
Maximum switching
voltage
|
110VDC
250VAC
|
Coil data
Coil
data
|
Nominal voltage
|
3VDC to 48VDC
|
Nominal power consumption2)
|
360mW
|
Operate voltage3)
|
75% of nominal voltage
|
Release voltage4)
|
10% of nominal voltage
|
1), 2), 3) The
values depend on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
10ms max. at nominal
voltage
|
Release time
|
5ms max. at nominal voltage
|
Initial insulation
resistance
|
100 M§Ù min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
1,000VACrms for 1 minute
2,500VACrms for 1 minute
|
Expected life
|
Mechanical:
Electrical:
|
More than 10,000,000
operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10¡55Hz dual amplitude:
1.5mm
10¡55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Heating Cold
|
+80¡¾2¡É 1000hrs
-40¡¾2¡É 1000hrs
|
Humidity
|
35% to 85% RH
|
Weight
|
9.5g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference,
part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
*Distributor stock item
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(§Ù¡¾10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(mW)
|
1 Form A
|
HR702NHDC03V
|
3
|
25
|
120
|
2.25
|
0.3
|
3.9
|
360
|
HR702NHDC05V
|
5
|
70
|
72
|
3.75
|
0.5
|
6.5
|
HR702NHDC06V
|
6
|
100
|
60
|
4.5
|
0.6
|
7.8
|
HR702NHDC09V
|
9
|
225
|
40
|
6.75
|
0.9
|
11.7
|
HR702NHDC12V
|
12
|
400
|
30
|
9.00
|
1.2
|
15.6
|
HR702NHDC24V
|
24
|
1,600
|
15
|
18.00
|
2.4
|
31.2
|
HR702NHDC48V
|
48
|
6,400
|
7.5
|
36.00
|
4.8
|
62.4
|
1
Form C
|
HR702ANHDC03V
|
3
|
25
|
120
|
2.25
|
0.3
|
3.9
|
360
|
HR702ANHDC05V
|
5
|
70
|
72
|
3.75
|
0.5
|
6.5
|
HR702ANHDC06V
|
6
|
100
|
60
|
4.5
|
0.6
|
7.8
|
HR702ANHDC09V
|
9
|
225
|
40
|
6.75
|
0.9
|
11.7
|
HR702ANHDC12V*
|
12
|
400
|
30
|
9.00
|
1.2
|
15.6
|
HR702ANHDC24V*
|
24
|
1,600
|
15
|
18.00
|
2.4
|
31.2
|
HR702ANHDC48V
|
48
|
6,400
|
7.5
|
36.00
|
4.8
|
62.4
|
Note: All values in the chart are measured at