8A, 1-Pole safety-oriented power relay
Features
1. 11.18mm distance between coil and contacts
terminal
2. High contacts capacity, 8A 125VAC |
|
Applications
1. Home appliances, Industrial control
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact data |
Arrangement |
1 Form A (SPST),1 Form C (SPDT) |
Contact material |
Ag alloy |
Initial contact resistance |
100m§Ù |
Rated load, resistive |
5A 30VDC
8A 125VAC
5A 250VAC |
Maximum switching current |
8A |
Maximum switching
capacity |
with DC voltage:
with AC voltage: |
150W
1,250VA |
Maximum switching voltage |
30VDC
200VAC |
Coil data
Coil
data
|
Nominal voltage
|
5VDC to 48VDC
|
Nominal power consumption2)
|
360mW
|
Operate voltage3)
|
75% of nominal voltage
|
Release voltage4)
|
10% of nominal voltage
|
1), 2), 3) The values depend on coil voltage,
see Part selection chart
General data
General
data
|
Operate time
|
10ms max. at nominal
voltage
|
Release time
|
10ms max. at nominal
voltage
|
Initial insulation
resistance
|
100 M§Ù min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
750VACrms for 1 minute
2,000VACrms for 1 minute
|
Expected life
|
Mechanical:
Electrical:
|
More than 10,000,000
operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10¡55Hz dual amplitude:
1.5mm
10¡55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Ambient temperature
|
£40¡É to £«85¡É (with no
icing)
|
Humidity
|
45% to 80% RH
|
Weight
|
9.5 g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference,
part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(§Ù¡¾10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(mW)
|
1
Form A
|
HR-CR5DC05A
|
5
|
70
|
71.5
|
3.75
|
0.5
|
5.5
|
360
|
HR-CR5DC06A
|
6
|
100
|
60.0
|
4.5
|
0.6
|
6.5
|
HR-CR5DC09A
|
9
|
225
|
40.0
|
6.75
|
0.9
|
9.9
|
HR-CR5DC12A
|
12
|
400
|
30.0
|
9.0
|
1.2
|
13.2
|
HR-CR5DC24A
|
24
|
1,600
|
15.0
|
18.0
|
2.4
|
26.4
|
HR-CR5DC48A
|
24
|
6,400
|
7.5
|
36.0
|
4.8
|
52.8
|
1
Form C
|
HR-CR5DC05C
|
5
|
70
|
71.5
|
3.75
|
0.5
|
5.5
|
360
|
HR-CR5DC06C
|
6
|
100
|
60.0
|
4.5
|
0.6
|
6.5
|
HR-CR5DC09C
|
9
|
225
|
40.0
|
6.75
|
0.9
|
9.9
|
HR-CR5DC12C
|
12
|
400
|
30.0
|
9.0
|
1.2
|
13.2
|
HR-CR5DC24C
|
24
|
1,600
|
15.0
|
18.0
|
2.4
|
26.4
|
HR-CR5DC48C
|
48
|
6,400
|
7.5
|
36.0
|
4.8
|
52.8
|
Note: All values in the chart are measured at
23¡É
|