8A, 1-Pole safety-oriented power relay

Features

1. 11.18mm distance between coil and contacts terminal
2. High contacts capacity, 8A 125VAC
Applications

1. Home appliances, Industrial control

Dimensions (mm)

To convert into inches, multiply by 0.03937

PC Board Layout

Copper-side view

Schematic

Copper-side view

Contact data

Contact data

Arrangement

1 Form A (SPST),1 Form C (SPDT)

Contact material

Ag alloy

Initial contact resistance

100m§Ù

Rated load, resistive

5A 30VDC
8A 125VAC
5A 250VAC

Maximum switching current

8A

Maximum switching
capacity

with DC voltage:
with AC voltage:

150W
1,250VA

Maximum switching voltage

30VDC
200VAC

Coil data

Coil data
Nominal voltage
5VDC to 48VDC
Nominal power consumption2)
360mW
Operate voltage3)
75% of nominal voltage
Release voltage4)
10% of nominal voltage

1), 2), 3) The values depend on coil voltage, see Part selection chart


General data

General data
Operate time
10ms max. at nominal voltage
Release time
10ms max. at nominal voltage
Initial insulation resistance
100 M§Ù min. (500VDC)
Dielectric strength
Between open contacts:
Between contacts & coil:
750VACrms for 1 minute
2,000VACrms for 1 minute
Expected life
Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated load
Vibration resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance
Functional:
Destructive:
10G min.
100G min.
Ambient temperature
£­40¡É to £«85¡É (with no icing)
Humidity
45% to 80% RH
Weight
9.5 g approx.

Note: The above figures are initial values

Part number description

Part number description is provided for reference, part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer specifications
are possible; please contact HR.

Part selection

Part number
Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
Max
voltage
(VDC)
Nominal
power
(mW)
1 Form A
HR-CR5DC05A
5
70
71.5
3.75
0.5
5.5
360
HR-CR5DC06A
6
100
60.0
4.5
0.6
6.5
HR-CR5DC09A
9
225
40.0
6.75
0.9
9.9
HR-CR5DC12A
12
400
30.0
9.0
1.2
13.2
HR-CR5DC24A
24
1,600
15.0
18.0
2.4
26.4
HR-CR5DC48A
24
6,400
7.5
36.0
4.8
52.8
1 Form C
HR-CR5DC05C
5
70
71.5
3.75
0.5
5.5
360
HR-CR5DC06C
6
100
60.0
4.5
0.6
6.5
HR-CR5DC09C
9
225
40.0
6.75
0.9
9.9
HR-CR5DC12C
12
400
30.0
9.0
1.2
13.2
HR-CR5DC24C
24
1,600
15.0
18.0
2.4
26.4
HR-CR5DC48C
48
6,400
7.5
36.0
4.8
52.8

Note: All values in the chart are measured at 23¡É

top