5A to 16A
low-profile power relay
Features
1. 4mm lower in height than
HRCR3 series
2. Wide contact arrangements 1 Form A to 2 Form C
3. 16A contact capacity
4. Sealed construction standard |
|
Applications
1. Home appliance, Industrial control
1 Pole type
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
2 Pole type
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact
data
|
Arrangement
|
1 Form A (SPST) to 2
Form C (DPDT)
|
Contact material
|
Ag Alloy
|
Initial contact resistance
|
100mงู max.
|
Type
|
2 Pole type
2 Form A, C
|
1 Pole type
|
Standard
1 Form A, C
|
K type
|
1 Form C
|
1 Form A
|
Rated load, resistive
|
5A 30VDC
5A 250VAC
TV-3
|
10A 30VDC
10A 250VAC
TV-5
|
10A 30VDC
10A 250VAC
|
16A 30VDC
16A 250VAC
|
TV-8
|
Maximum switching
current
|
5A
|
10A
|
16A
|
16A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
150W
1,250VA
|
300W
2,500VA
|
300W
2,500VA
|
480W
3,840VA
|
Maximum switching
voltage
|
250VAC Resistive
|
Minimum switching
rating1)
|
100mA 5VDC
|
1) Min.
Switching Load mentioned above are reference values. Therefore it is recommended
to
perform the confirmation test with the actual load before production since reference
values may
vary according to switching frequencies, environmental conditions and expected
reliability levels.
Coil data
Coil
data
|
Nominal voltage
|
5VDC to 48VDC
|
Nominal power consumption2)
|
530mW, 720mW
|
Operate voltage3)
|
80% of nominal voltage
|
Release voltage4)
|
10% of nominal voltage
|
2), 3), 4) The
values depend on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
15ms max. at nominal
voltage
|
Release time
|
8ms max. at nominal voltage
|
Initial insulation
resistance
|
1,000 Mงู min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
1,000VACrms for 1 minute
5,000VACrms for 1 minute
|
Surge strength
|
Between contacts & coil:
|
10,000V
|
Expected life
|
Mechanical:
Electrical:
|
More than 10,000,000
operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10กญ55Hz dual amplitude:
1.5mm
10กญ55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Ambient temperature
|
ฃญ40กษ to ฃซ70กษ (with no
icing)
|
Humidity
|
45% to 85% RH
|
Weight
|
13g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference,
part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
กเ Fill in the codes to the part number by selecting
them from the part number description
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(งูกพ10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(mW)
|
Standard coil
1 Form C, 1 Form A, 2 Form C, 2 Form A
|
HR-CR3Aกเกเ DC05กเกเ
|
5
|
35
|
144
|
4.0
|
0.5
|
6.5
|
720
|
HR-CR3Aกเกเ DC06กเกเ
|
6
|
50
|
120
|
4.8
|
0.6
|
7.8
|
HR-CR3Aกเกเ DC09กเกเ
|
9
|
112
|
80
|
7.2
|
0.9
|
11.7
|
HR-CR3Aกเกเ DC12กเกเ
|
12
|
200
|
60
|
9.6
|
1.2
|
15.6
|
HR-CR3Aกเกเ DC18กเกเ
|
18
|
450
|
40
|
14.4
|
1.8
|
23.4
|
HR-CR3Aกเกเ DC24กเกเ
|
24
|
800
|
30
|
19.2
|
2.4
|
31.2
|
HR-CR3Aกเกเ DC48กเกเ
|
48
|
3,200
|
15
|
38.4
|
4.8
|
62.4
|
|
Sensitive
coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
|
HR-CR3Aกเกเ DC05กเกเ H
|
5
|
47
|
106
|
4.0
|
0.5
|
6.5
|
530
|
HR-CR3Aกเกเ DC06กเกเ H
|
6
|
68
|
88
|
4.8
|
0.6
|
7.8
|
HR-CR3Aกเกเ DC09กเกเ H
|
9
|
153
|
59
|
7.2
|
0.9
|
11.7
|
HR-CR3Aกเกเ DC12กเกเ H
|
12
|
273
|
44
|
9.6
|
1.2
|
15.6
|
HR-CR3Aกเกเ DC18กเกเ H
|
18
|
620
|
29
|
14.4
|
1.8
|
23.4
|
HR-CR3Aกเกเ DC24กเกเ H
|
24
|
1,085
|
22.1
|
19.2
|
2.4
|
31.2
|
HR-CR3Aกเกเ DC48กเกเ H
|
48
|
4,350
|
11.0
|
38.4
|
4.8
|
62.4
|
Note: All values in the chart are measured at
23กษ
|