Small 1-pole 3-10A relay

Features

1. High electrical noise immunity
2. Up to 10A switching capacity in a compact package
3. Dielectric strength 4,000V, surge strength 8,000V
4. Sensitive 200mW and standard 450mW available

Approx. the actual size
Applications

1. Home appliances, Industrial control.

Dimensions (mm)

To convert into inches, multiply by 0.03937

PC Board Layout

Copper-side view


Schematic

Copper-side view

Contact data

Contact data

Arrangement

1 Form A (SPST)

1 Form C (SPDT)

Contact material

Ag Alloy

Initial contact resistance

100m§Ù max.

Rated load, resistive

5A 30VDC
10A 125VAC
5A 250VAC
NO
NC
5A 30VDC
10A 125VAC
5A 250VAC
3A 30VDC
5A 125VAC
3A 250VAC
Maximum switching current
10A
10A
5A

Maximum switching
capacity

with DC voltage:
with AC voltage:

150W
1,250VA

150W
1,250VA
90W
750VA

Maximum switching voltage

110VDC
250VAC

Coil data

Coil data
Nominal voltage
3VDC to 24VDC
Nominal power consumption1)
200mW, 450mW
Operate voltage2)
75% of nominal voltage
Release voltage3)
5% of nominal voltage

1), 2), 3) The values depend on coil voltage, see Part selection chart

General data

General data
Operate time
8ms max. at nominal voltage
Release time
5ms max. at nominal voltage
Initial insulation resistance
1,000 M§Ù min. (500VDC)
Dielectric strength
Between open contacts:
Between contacts & coil:
1,000VACrms for 1 minute
4,000VACrms for 1 minute
Surge strength
Between contacts & coil:
8,000V
Expected life
Mechanical:
Electrical:
More than 10,000,000 operations
More than 100,000 operations at rated load
Vibration resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 1.5mm
10¡­55Hz dual amplitude: 1.5mm
Shock resistance
Functional:
Destructive:
10G min.
100G min.
Ambient temperature
£­40¡É to £«70¡É (with no icing)
Humidity
35% to 85% RH
Weight
6 g approx.

Note: The above figures are initial values

Part number description

Part number description is provided for reference, part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer specifications
are possible; please contact HR.

Part selection

Part number
Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
Max
voltage
(VDC)
Nominal
power
(mW)
Standard coil, 1 Form A
HR96A 03
3
20
150
2.25
0.15
3.9
450
HR96A 05
5
56
90
3.75
0.25
5.5
HR96A 06
6
80
75
4.50
0.3
6.6
HR96A 09
9
180
50
6.75
0.45
9.9
HR96A 12
12
320
37.5
9.00
0.6
13.2
HR96A 18
18
720
25
13.5
0.9
19.8
HR96A 24
24
1,280
18.75
18.0
1.2
26.4
Sensitive coil, 1 Form A
HR96A 03H
3
45
66.7
2.25
0.15
3.3
200
HR96A 05H
5
125
40.0
3.75
0.25
5.5
HR96A 06H
6
180
33.3
4.50
0.3
6.6
HR96A 09H
9
400
22.5
6.75
0.45
9.9
HR96A 12H
12
720
16.7
9.00
0.6
13.2
HR96A 18H
18
1,600
11.2
13.5
0.9
19.8
HR96A 24H
24
2,800
8.57
18.0
1.2
26.4
Standard coil, 1 Form C
HR96A 03
3
20
150
2.25
0.15
3.9
450
HR96A 05
5
56
90
3.75
0.25
5.5
HR96A 06
6
80
75
4.50
0.3
6.6
HR96A 09
9
180
50
6.75
0.45
9.9
HR96A 12
12
320
37.5
9.00
0.6
13.2
HR96A 18
18
720
25
13.5
0.9
19.8
HR96A 24
24
1,280
18.75
18.0
1.2
26.4
Sensitive coil, 1 Form C
HR96A 03H
3
45
66.7
2.25
0.15
3.3
200
HR96A 05H
5
125
40.0
3.75
0.25
5.5
HR96A 06H
6
180
33.3
4.50
0.3
6.6
HR96A 09H
9
400
22.5
6.75
0.45
9.9
HR96A 12H
12
720
16.7
9.00
0.6
13.2
HR96A 18H
18
1,600
11.2
13.5
0.9
19.8
HR96A 24H
24
2,800
8.57
18.0
1.2
26.4

Note: All values in the chart are measured at 23¡É

top