Small 1-pole 3-10A relay
Features
1. High electrical noise immunity
2. Up to 10A switching capacity in a compact package
3. Dielectric strength 4,000V, surge strength 8,000V
4. Sensitive 200mW and standard 450mW available |
|
Approx. the actual size |
Applications
1. Home appliances, Industrial control.
Dimensions (mm)
To convert into inches, multiply by 0.03937
PC Board Layout
Copper-side view
Schematic
Copper-side view
Contact data
Contact
data
|
Arrangement
|
1 Form A (SPST)
|
1 Form C (SPDT)
|
Contact material
|
Ag Alloy
|
Initial contact
resistance
|
100m§Ù max.
|
Rated load, resistive
|
5A 30VDC
10A 125VAC
5A 250VAC
|
NO
|
NC
|
5A 30VDC
10A 125VAC
5A 250VAC
|
3A 30VDC
5A 125VAC
3A 250VAC
|
Maximum switching
current
|
10A
|
10A
|
5A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
150W
1,250VA
|
150W
1,250VA
|
90W
750VA
|
Maximum switching
voltage
|
110VDC
250VAC
|
Coil
data
Coil
data
|
Nominal voltage
|
3VDC to 24VDC
|
Nominal power consumption1)
|
200mW, 450mW
|
Operate voltage2)
|
75% of nominal voltage
|
Release voltage3)
|
5% of nominal voltage
|
1), 2), 3) The
values depend on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
8ms max. at nominal voltage
|
Release time
|
5ms max. at nominal voltage
|
Initial insulation
resistance
|
1,000 M§Ù min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
1,000VACrms for 1 minute
4,000VACrms for 1 minute
|
Surge strength
|
Between contacts & coil:
|
8,000V
|
Expected life
|
Mechanical:
Electrical:
|
More than 10,000,000 operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10¡55Hz dual amplitude: 1.5mm
10¡55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Ambient temperature
|
£40¡É to £«70¡É (with no icing)
|
Humidity
|
35% to 85% RH
|
Weight
|
6 g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference,
part number cannot be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(§Ù¡¾10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(mW)
|
Standard coil,
1 Form A
|
HR96A 03
|
3
|
20
|
150
|
2.25
|
0.15
|
3.9
|
450
|
HR96A 05
|
5
|
56
|
90
|
3.75
|
0.25
|
5.5
|
HR96A 06
|
6
|
80
|
75
|
4.50
|
0.3
|
6.6
|
HR96A 09
|
9
|
180
|
50
|
6.75
|
0.45
|
9.9
|
HR96A 12
|
12
|
320
|
37.5
|
9.00
|
0.6
|
13.2
|
HR96A 18
|
18
|
720
|
25
|
13.5
|
0.9
|
19.8
|
HR96A 24
|
24
|
1,280
|
18.75
|
18.0
|
1.2
|
26.4
|
Sensitive
coil, 1 Form A
|
HR96A 03H
|
3
|
45
|
66.7
|
2.25
|
0.15
|
3.3
|
200
|
HR96A 05H
|
5
|
125
|
40.0
|
3.75
|
0.25
|
5.5
|
HR96A 06H
|
6
|
180
|
33.3
|
4.50
|
0.3
|
6.6
|
HR96A 09H
|
9
|
400
|
22.5
|
6.75
|
0.45
|
9.9
|
HR96A 12H
|
12
|
720
|
16.7
|
9.00
|
0.6
|
13.2
|
HR96A 18H
|
18
|
1,600
|
11.2
|
13.5
|
0.9
|
19.8
|
HR96A 24H
|
24
|
2,800
|
8.57
|
18.0
|
1.2
|
26.4
|
Standard
coil, 1 Form C
|
HR96A 03
|
3
|
20
|
150
|
2.25
|
0.15
|
3.9
|
450
|
HR96A 05
|
5
|
56
|
90
|
3.75
|
0.25
|
5.5
|
HR96A 06
|
6
|
80
|
75
|
4.50
|
0.3
|
6.6
|
HR96A 09
|
9
|
180
|
50
|
6.75
|
0.45
|
9.9
|
HR96A 12
|
12
|
320
|
37.5
|
9.00
|
0.6
|
13.2
|
HR96A 18
|
18
|
720
|
25
|
13.5
|
0.9
|
19.8
|
HR96A 24
|
24
|
1,280
|
18.75
|
18.0
|
1.2
|
26.4
|
Sensitive coil,
1 Form C
|
HR96A 03H
|
3
|
45
|
66.7
|
2.25
|
0.15
|
3.3
|
200
|
HR96A 05H
|
5
|
125
|
40.0
|
3.75
|
0.25
|
5.5
|
HR96A 06H
|
6
|
180
|
33.3
|
4.50
|
0.3
|
6.6
|
HR96A 09H
|
9
|
400
|
22.5
|
6.75
|
0.45
|
9.9
|
HR96A 12H
|
12
|
720
|
16.7
|
9.00
|
0.6
|
13.2
|
HR96A 18H
|
18
|
1,600
|
11.2
|
13.5
|
0.9
|
19.8
|
HR96A 24H
|
24
|
2,800
|
8.57
|
18.0
|
1.2
|
26.4
|
Note: All values in the chart are measured at