World famous 30A 1,2-pole heavy duty power relay
Features
1. Designed to match magnetic contactor capabilityat a much lower cost
|
2. Multi contact arrangement
3. Very low operation sound level
4. Plastic cover standard for 2 Form A and 2 Form C |
|
|
Applications
1. Heater, Motor, Lamp load, Compressor
Dimensions (mm)
To convert into inches, multiply by 0.03937
Dimensions (mm)
To convert into inches, multiply by 0.03937
Schematic
Top view
Mounting Layout
Contact data
Contact
data
|
Arrangement
|
1 Form C, 1 Form X, 2 Form A, 2 Form
C
|
Contact material
|
Silver Cadium Oxide
|
Initial contact resistance
|
100m§Ù max.
|
Rated load, resistive
|
30A 24VDC
30A 250VAC
|
Maximum carry current
|
30A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
480W
7,500VA
|
Maximum switching
voltage
|
110VDC
250VAC
|
Coil data
Coil data
|
Nominal voltage
|
6VDC to 100VDC
6VAC to 240VAC
|
Nominal power consumption1)
|
DC Coil:
AC Coil:
|
2.4W to 2.8W approx.
9.6VA (60Hz) approx.
|
Operate voltage2)
|
80% of nominal voltage
|
Release voltage3)
|
DC Coil:
AC Coil:
|
10% of nominal voltage
30% of nominal voltage
|
1), 2), 3) The values depend
on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
30ms max. at nominal voltage
|
Release time
|
30ms max. at nominal voltage
|
Initial insulation
resistance
|
100 M§Ù min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
2,000VACrms
2,500VACrms
|
Expected life
|
Mechanical:
Electrical:
|
More than 5,000,000 operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10¡55Hz dual amplitude: 3.3mm
10¡55Hz dual amplitude: 5.0mm
|
Shock resistance
|
Functional:
Destructive:
|
20G min.
100G min.
|
Ambient temperature
|
DC Coil:
AC Coil:
|
£55¡É to £«80¡É
£55¡É to £«45¡É
|
Humidity
|
5% to 85% RH
|
Weight
|
1 Form C, 1 Form X: 200g approx.
2 Form A: 250g approx.
2 Form C: 300g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference, part number
can not be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications are
possible; please contact HR.
Part selection
Distributor stock items
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(§Ù¡¾10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(W,VA)
|
50Hz
|
60Hz
|
1 Form C, 1
Form X, 2 Form A, 2 Form C
|
HR723-¡à¡àDC006
|
6
|
12.6
|
470
|
4.8
|
0.6
|
6.6
|
2.4 to 2.8
approx.
|
HR723-¡à¡àDC012
|
12
|
57
|
210
|
9.6
|
1.2
|
13.2
|
HR723-¡à¡àDC024
|
24
|
233
|
103
|
19.2
|
2.4
|
26.4
|
HR723-¡à¡àDC048
|
48
|
986
|
50
|
38.4
|
4.8
|
52.8
|
HR723-¡à¡àDC100
|
100
|
4,055
|
25
|
80.0
|
10.0
|
110
|
HR723-¡à¡àAC006
|
6
|
-
|
1,640
|
2,000
|
4.8
|
1.8
|
6.6
|
9.6
(60Hz)
Approx.
|
HR723-¡à¡àAC012
|
12
|
-
|
820
|
1,000
|
9.6
|
3.6
|
13.2
|
HR723-¡à¡àAC024
|
24
|
-
|
410
|
500
|
19.2
|
7.2
|
26.4
|
HR723-¡à¡àAC050
|
50
|
-
|
192
|
232
|
40.0
|
15.0
|
55.0
|
HR723-¡à¡àAC110
|
110
|
-
|
87.2
|
104.6
|
88.0
|
33
|
121
|
HR723-¡à¡àAC220
|
220
|
-
|
42
|
50
|
176
|
66
|
242
|
HR723-¡à¡àAC240
|
240
|
-
|
38
|
45.6
|
192
|
72
|
264
|
Note: All values in the chart are measured at 23¡É
|