World famous 30A 1,2-pole heavy duty power relay

Features

1. Designed to match magnetic contactor capabilityat a much lower cost

2. Multi contact arrangement
3. Very low operation sound level
4. Plastic cover standard for 2 Form A and 2 Form C
 
Applications

1. Heater, Motor, Lamp load, Compressor

Dimensions (mm)

To convert into inches, multiply by 0.03937


Dimensions (mm)

To convert into inches, multiply by 0.03937

Schematic

Top view

Mounting Layout

Contact data

Contact data
Arrangement
1 Form C, 1 Form X, 2 Form A, 2 Form C
Contact material
Silver Cadium Oxide
Initial contact resistance
100m§Ù max.
Rated load, resistive
30A 24VDC
30A 250VAC
Maximum carry current
30A
Maximum switching capacity
with DC voltage:
with AC voltage:
480W
7,500VA
Maximum switching voltage
110VDC
250VAC

Coil data

Coil data
Nominal voltage
6VDC to 100VDC
6VAC to 240VAC
Nominal power consumption1)
DC Coil:
AC Coil:
2.4W to 2.8W approx.
9.6VA (60Hz) approx.
Operate voltage2)
80% of nominal voltage
Release voltage3)
DC Coil:
AC Coil:
10% of nominal voltage
30% of nominal voltage

1), 2), 3) The values depend on coil voltage, see Part selection chart

General data

General data
Operate time
30ms max. at nominal voltage
Release time
30ms max. at nominal voltage
Initial insulation resistance
100 M§Ù min. (500VDC)
Dielectric strength
Between open contacts:
Between contacts & coil:
2,000VACrms
2,500VACrms
Expected life
Mechanical:
Electrical:
More than 5,000,000 operations
More than 100,000 operations at rated load
Vibration resistance
Functional:
Destructive:
10¡­55Hz dual amplitude: 3.3mm
10¡­55Hz dual amplitude: 5.0mm
Shock resistance
Functional:
Destructive:
20G min.
100G min.
Ambient temperature
DC Coil:
AC Coil:
£­55¡É to £«80¡É
£­55¡É to £«45¡É
Humidity
5% to 85% RH
Weight
1 Form C, 1 Form X: 200g approx.
2 Form A: 250g approx.
2 Form C: 300g approx.

Note: The above figures are initial values

Part number description

Part number description is provided for reference, part number can not be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer specifications are
possible; please contact HR.

Part selection

Distributor stock items

Part number
Nominal
voltage
(VDC)
Coil
resistance
(§Ù¡¾10%)
Nominal
current
(mA)
Must operate
voltage
(VDC)
Must release
voltage
(VDC)
Max
voltage
(VDC)
Nominal
power
(W,VA)
50Hz
60Hz
1 Form C, 1 Form X, 2 Form A, 2 Form C
HR723-¡à¡àDC006
6
12.6
470
4.8
0.6
6.6
2.4 to 2.8
approx.
HR723-¡à¡àDC012
12
57
210
9.6
1.2
13.2
HR723-¡à¡àDC024
24
233
103
19.2
2.4
26.4
HR723-¡à¡àDC048
48
986
50
38.4
4.8
52.8
HR723-¡à¡àDC100
100
4,055
25
80.0
10.0
110
HR723-¡à¡àAC006
6
-
1,640
2,000
4.8
1.8
6.6
9.6
(60Hz)
Approx.
HR723-¡à¡àAC012
12
-
820
1,000
9.6
3.6
13.2
HR723-¡à¡àAC024
24
-
410
500
19.2
7.2
26.4
HR723-¡à¡àAC050
50
-
192
232
40.0
15.0
55.0
HR723-¡à¡àAC110
110
-
87.2
104.6
88.0
33
121
HR723-¡à¡àAC220
220
-
42
50
176
66
242
HR723-¡à¡àAC240
240
-
38
45.6
192
72
264

Note: All values in the chart are measured at 23¡É