Multi contact arrangement general purpose relay
Features
|
|
1. Sequence control to power applications
2. A wide range of variations and options available
3. Arc suppression barrier, 3 and 4 pole types
4. Conforms to various safety standard |
Applications
1. Process controls, Sequence controls data processing
Dimensions (mm) and schematic
To convert into inches, multiply by 0.03937
Contact data
Contact
data
|
Arrangement
|
1 Form C (SPDT) to 4
Form C (4PDT)
|
Contact material
|
AgCdO
|
Initial contact
resistance
|
50mงู max.
|
Rated load,
resistive
|
1,2,3 Form C
|
4 Form C
|
5A 24VDC
5A 240VAC
|
3A 24VDC
3A 240VAC
|
Maximum carry
current
|
5A
|
3A
|
Maximum switching
capacity
|
with DC voltage:
with AC voltage:
|
120W
1,200VA
|
72W
720VA
|
Maximum switching
voltage
|
125VDC
250VAC
|
Minimum switching
rating1)
|
100mA 5VDC
|
1) Min. Switching Load
mentioned above are reference values. Therefore it is recommended to
perform the confirmation test with the actual load before production since reference
values may
vary according to switching frequencies, environmental conditions and expected
reliability levels.
Coil data
Coil
data
|
Nominal voltage
|
6VDC to 110VDC
6VAC to 240VAC
|
Nominal power
consumption2)
|
DC Coil:
AC Coil:
|
0.9W approx.
0.9VA to 1.2VA (60Hz) approx.
|
Operate voltage3)
|
80% of nominal voltage
|
Release voltage4)
|
DC Coil:
AC Coil:
|
10% of nominal voltage
30% of nominal voltage
|
2), 3), 4) The values depend
on coil voltage, see Part selection chart
General data
General
data
|
Operate time
|
20ms max. at nominal voltage
|
Release time
|
20ms max. at nominal voltage
|
Initial insulation
resistance
|
100 Mงู min. (500VDC)
|
Dielectric strength
|
Between open
contacts:
Between contacts & coil:
|
1,000Vrms for 1 minute
1,500Vrms for 1 minute
|
Expected life
|
Mechanical:
Electrical:
|
More than 1,000,000 operations
More than 100,000 operations at rated load
|
Vibration resistance
|
Functional:
Destructive:
|
10กญ55Hz dual amplitude: 1.5mm
10กญ55Hz dual amplitude: 1.5mm
|
Shock resistance
|
Functional:
Destructive:
|
10G min.
100G min.
|
Ambient temperature
|
ฃญ35กษกญฃซ55กษ (with no icing)
|
Humidity
|
35% to 85% RH
|
Weight
|
33g approx.
|
Note: The above figures are initial values
Part number description
Part number description is provided for reference, part number
can not be arbitrarily composed.
Refer to the part numbers shown in the table below. Special designs to customer
specifications
are possible; please contact HR.
Part selection
กเ Fill in the codes to the part number by selecting them from
the in part number description
Part number
|
Nominal
voltage
(VDC)
|
Coil
resistance
(งูกพ10%)
|
Nominal
current
(mA)
|
Must operate
voltage
(VDC)
|
Must release
voltage
(VDC)
|
Max
voltage
(VDC)
|
Nominal
power
(W,VA)
|
50Hz
|
60Hz
|
DC Coil
|
HR705-กเกเกเ 6VDC
|
6
|
40
|
150
|
4.8
|
0.6
|
6.6
|
0.9
approx.
|
HR705-กเกเกเ 12VDC
|
12
|
160
|
75
|
9.6
|
1.2
|
13.2
|
HR705-กเกเกเ 24VDC
|
24
|
650
|
36.9
|
19.2
|
2.4
|
26.4
|
HR705-กเกเกเ 48VDC
|
48
|
2,600
|
18.5
|
38.4
|
4.8
|
52.8
|
HR705-กเกเกเ 100/110VDC
|
100/110
|
11,000
|
9.1/10
|
80/88
|
10/11
|
110/121
|
1.1 approx.
|
AC
Coil
|
HR705-กเกเกเ 6VAC
|
6
|
12.2
|
214.1
|
183
|
4.8
|
1.8
|
6.6
|
1.0 to 1.2
(60Hz)
approx.
|
HR705-กเกเกเ 12VAC
|
12
|
46
|
106.5
|
91
|
9.6
|
3.6
|
13.2
|
HR705-กเกเกเ 24VAC
|
24
|
180
|
53.8
|
46
|
19.2
|
7.2
|
26.4
|
HR705-กเกเกเ 50VAC
|
48
|
788
|
25.7
|
22
|
40.0
|
15
|
55
|
HR705-กเกเกเ 100/110VAC
|
100/110
|
3,750
|
11.7/12.9
|
10/11
|
80/88
|
30/33
|
110/121
|
0.9 to 1.2
(60Hz)
approx.
|
HR705-กเกเกเ 110/120VAC
|
110/120
|
4,430
|
9.9/10.8
|
8.4/9.2
|
88/96
|
33/36
|
121/132
|
HR705-กเกเกเ 200/220VAC
|
200/220
|
12,950
|
6.2/6.8
|
5.3/5.8
|
160/176
|
60/66
|
220/242
|
HR705-กเกเกเ 220/240VAC
|
220/240
|
18,790
|
4.8/5.3
|
4.2/4.6
|
176/192
|
66/72
|
242/264
|
Note: All values in the chart are measured at 23กษ
|